Input :
- 240/415VAC, 20A, 3 phase, 50Hz
Output :
- 240/415VAC, 20A, 3 phase, 50Hz to be connected to resistive, inductive and capacitive loading units
POWER FACTOR CORRECTION PANEL
- 3 x 22mm Pilot Lamp (R/Y/B) Main Phase Lamp
- 1 x Power Factor Regulator/Controller 6 steps
- 6 x Capacitor Banks of assorted ratings 1KVAr
- 1 x Circuit Breaker 32A TP
- 6 x Circuit Breaker 16A TP
- 6 x Magnetic Contactors 240V
- 6 x Indicating lights 240V
- 1 x 32/5A Class 3, 5VA C/T Coil
- 1 x Three Phase Power Quality Meter
- Display Type: HD LCD Display
- Real-Time Measurement:
- Phase voltage: V1, V2, V3, Vlnavg
- Line voltage: V12, V23, V31, Vllavg
- Current: I1, I2, I3, Iavg
- Active power: per phase and total
- Reactive power: per phase and total
- Apparent power: per phase and total
- Power factor: per phase and total
- Energy And Demand
Power Quality Analysis:
- Voltage unbalance, Current unbalance
- Voltage THD, harmonic distortion
- Individual harmonics, Crest factor, K factor
Communication:
- Ethernet 10/100M network port
- RS485 communication port
- MODBUS RTU communication protocol
- PowerMeter Management Software Interface
POWER MANAGEMENT SOFTWARE
- PC management software; web browse data
- True-RMS measuring parameters
- ANSI and IEC 0.2 accuracy class
- Power quality analysis
- 4 quadrant energy
- Data logging
- Measure individual harmonics from 2nd to 49th
- TOU, 4 Tariffs, 6 Seasons, 6 Schedules
Trend Logging:
- Phase voltage, Line voltage, Current
- Active, Reactive, Apparent power
- Power factor, Frequency
- Three-phase unbalance
- Active, Reactive, Apparent energy
Settable Logging Interval:
- Logging from 1min to 60min
Software Accessibility:
- 4 Tariffs (DataLog) Sharp, peak, flat, valley
RESISTIVE LOAD UNIT
- Single-Three phase Resistive Load 7 steps variable per phase
- Max Power: 3 x 700 Watt
- Voltage: 240/415 Volt
- Unit Type: Top Table
Main Characteristics:
- Can be connected in Series, Parallel, Star and Delta configurations
- Can be connected to AC Single and 3 Phase sources
- Controlled by 3 x 3 circuit breaker switches for 7 steps selection
CAPACITIVE LOAD UNIT
- Single-Three phase Capacitive Load 7 steps variable per phase
- Max Power: 3 x 700VA
- Voltage: 240/415 Volt
- Unit Type: Top Table
Main Characteristics:
- Can be connected in Series, Parallel, Star and Delta configurations
- Can be connected to AC Single and 3 Phase sources
- Controlled by 3 x 3 circuit breaker switches for 7 steps selection
INDUCTIVE LOAD UNIT
- Single-Three phase Inductive Load 7 steps variable per phase
- Max Power: 3 x 700VA
- Voltage: 240/415 Volt
- Unit Type: Top Table
Main Characteristics:
- Can be connected in Series, Parallel, Star and Delta configurations
- Can be connected to AC Single and 3 Phase sources
- Controlled by 3 x 3 circuit breaker switches for 7 steps selection
4MM SAFETY STACKABLE TEST LEAD SET
- The set consists of 25 leads in 5 different coded colors (Red, Yellow, Blue, Black and Green)
- Leads are capable of 15A current safety plugs
- Safety Terminal Plug: 4mm
- 250mm x 7 units
- 500mm x 6 units
- 1000mm x 6 units
- 1500mm x 6 units