ATENG 10958 — Optical Fibre Transmission and Reception (Keyword-density extraction)
1)Hardware:
1.1) DAIB. Data Acquisition Interface Box:
Metallic box. Dimensions: 310 x 220 x 145 mm. approx.
Front panel:
16 Analog inputs (1 block with 12 voltage channels and 1 block with 2 current channels (4
connections)).
Sampling velocity 1,250,000 samples per second for EDAS/VIS 1.25 Version.
Sampling velocity 250,000 samples per second for EDAS/VIS 0.25 Version.
2 Analog outputs.
24 Digital inputs/outputs, configurable as inputs or outputs, with 24 state led indicators.
These digital inputs/outputs are grouped in three ports of eight channels (P0, P1 and P3).
4 Digital signal switches 0-5V. 2 Analog signal potentiometers ± 12V.
Main ON/OFF switch.
DAIB
Inside: Internal power supply of 12 and 5 V. Potentiometer.
Back panel: Power supply connector. SCSI connector (for data acquisition board).
Connecting cables.
1.2) DAB. Data Acquisition Board:
For EDAS/VIS 1.25 Version:
PCI Data acquisition board (National Instruments) to be placed in a computer slot. Bus PCI.
Analog input: Number of channels= 16 single-ended or 8 differential. Resolution=16 bits, 1 in
Sampling rate up to: 1,250,000 S/s (samples per second). Input range
(V)=± 10V. Data transfers=DMA, interrupts, programmed I/0. DMA channels=6.
Analog output: Number channels=2. Resolution=16 bits, 1 in 65536. Max. output rate up to:
833KS/s. Output range(V)=± 10V. Data transfers=DMA, interrupts, programmed
I/0.
Digital Input/Output:Numbers of channels=24 inputs/outputs. Port 0 up to 8 Mhz.
Sampling rate up to: 250,000 S/s (samples per second).
Analog output: Max. output rate up to:10 KS/s.
Digital Input/Output: Number of channels=24 inputs/outputs. Port 0 up to 1 Mhz.
EDAS/VIS-SOF. Data Acquisition and Virtual Instrumentation Software:
Compatible with actual Windows operating systems. Amicable graphical frame.
Configurable software allowing the temporal/frequency representation of the different inputs
and outputs. Visualization of a voltage of the circuits on the computer screen.
It allows data store in a file, print screens and reports of the signals at any time.
Measurement, analysis, visualization, representation and report of results.
Set of Virtual Instruments:
Oscilloscope:
Channels: 12 simultaneous. Maximum input voltage: ± 10V.
All 12 input channels could be scaled to compare signal with different voltage levels.
“Math Menu” with operations as Addition, Subtraction, Multiplication and Division, between any of
the 12 oscilloscope channels.
Function Generator:
Two independent signal generators, for sinusoidal, triangular, saw tooth and square.
Channels: 2 (allowing working simultaneously). Maximum output voltage: ± 10V.
It includes a graph where an output signal for each channel is shown.
Spectrum Analyzer:
Channels: 12 (simultaneous). Max. voltage: ± 10V. Spectrum analyzer: based on the FFT.